CONDENSER FAN SPEED CONTROLLERS Type RGEGENERAL DESCRIPTION•The most suitable for controlling the speed of a condenser fan of freezing and refrigeration condensing unit, package air conditioner and other units which are operated throughout a year.•Keep condensing pressure constant in winter and intermediate seasons for stable operation.•One of the following operation models is selectable when low speed. Minimum Speed Operation Cut off Operation•Excellent noise-resisting design.•Applicable to the external forced operation switch.TYPE NUMBER SELECTION*1: The pressure at which the control delivers 95% output effective voltage (VRMS).*2: Pressure width where effective voltage corresponds to the minimum speed or causes cut off operation・Min. speed: Fan motor will be kept running at the specific value (V%) when pressure band increase more than E.P.B.・Cut off: Fan motor will be stopped when pressure decrease to the specific value (V%) for R.M.S.・For other pressure set values or min. speed/cut off set values, please contact us. mark applicable listed (available upon request)Single-phase typeThree-phase typeOPERATIONThe operating characteristic may vary according to the voltage, frequency, and fan motor characteristics.① Single-phase type② Three-phase type50Hz at 230V45z at 230VH06E.P.B.(Fixed).S.M.R egatloV evitceffE)%V(1009535PressureMin. SpeedMax. SpeedF.V.S.(Adjustable)ffO tuCE.P.B.(Fixed).S.M.R egatloV evitceffE)%V(1009535PressureMin. SpeedMax. SpeedF.V.S.(Adjustable)ffO tuCSPECIFICATIONS •Max.working pressure: 4.7MPa•Control method: Phase control•Enclosure: IP54Catalog No.F.V.S. Setting (MPa)E.P.B. (MPa) RefrigerantsElectrical RatingsFunctionAmbient Temp. (°C)OperationWt. (kg)Factory SetAdjusting RangeMin.Max.AmpereRGE–Z1L4–71.90.82.8Fixed 0.6R22, R404A, R407CSingle phase200 to 240V. AC50/60Hz0.2 to 3AAt approx. 45% (50Hz)at approx. 35% (60Hz)Cut Off or Minimum Speed function is selectable with changeover switch.Default setting: Cut Off−20 to 55①0.36RGE–Z1L6–73.21.63.9Fixed 0.9R410ARGE–Z1N4–71.90.82.8Fixed 0.4R22, R404A, R407C0.2 to 4A0.5RGE–Z1N6–73.21.63.9Fixed 0.8R410ARGE–Z1P4–71.90.82.8Fixed 0.4R22, R404A, R407C0.2 to 6A0.54RGE–Z1P6–73.21.63.9Fixed 0.8R410ARGE–Z1Q4–71.90.82.8Fixed 0.4R22, R404A, R407C0.2 to 8A0.58RGE–Z1Q6–73.21.63.9Fixed 0.8R410ARGE–Z3R4–71.60.82.8Fixed 0.4R22, R404A, R407CThree phase 200 to 240V. AC 50/60Hz0.2 to 5AAt approximately 35%, Cut Off or Minimum Speed function is selectable with changeover switch.Default setting: Min. Speed−20 to 50②1.4RGE–Z3R6–73.21.63.9Fixed 0.8R410ARGE–Z3T4–71.60.82.8Fixed 0.6R22, R404A, R407C0.2 to 7A1.53RGE–Z3T6–73.21.63.9Fixed 0.8R410ARGE–X3R4–71.60.82.8Fixed 0.4R22, R404A, R407CThree phase 380 to 415V. AC 50/60Hz0.2 to 5A−15 to 501.4RGE–X3R6–73.21.63.9Fixed 0.8R410A*1*2

元のページ 

10秒後に元のページに移動します

※このページを正しく表示するにはFlashPlayer10.2以上が必要です