FLOW SENSORSHigh Volume OEM Item Type ELKGENERAL DESCRIPTION•Turbine type flow sensor having an impeller to rotate in proportion to flow rate.•For burner On-Off of hot water supply system, accu-mulation of automatic hot water supply.•Pulse output corresponding flow rate.•Max. working pressure: 1MPa•Fluid temperature: 0 to 80°C (No frozen)•Rated voltage: 4.5 to 13.2 V. DC•Housing body material: PPS•Installation is vertical riser piping or horizontal piping.SPECIFICATIONSFLOW RATE–OUTPUT PULSE CHARACTERISTICSDIMENSIONS001050100Horizontal pipingVertical riser pipingOutput Pulse(pps)1.5510Flow rate(L/min)15No.3 Black: GNDTerminal Cable ColorNo.2 Yellow: VoutNo.1 Red: Vcc1505030゜30゜φ20φ30Inletφ30φ25φ25φ19+0.06-0.1+0.06-0.1Unit: mmHigh Volume OEM ItemCatalog No.Range of Flow Rate (L/min)Flow Rate–Output Pulse CharacteristicsOutput ModeMax. Output Current (mA)Wt. (kg)Based Flow Rate (L/min)Vertical riser piping (pps)Horizontal piping (pps)ELK–05081.5 to 251.59.6±27.7±2Open Collector150.0251068.7±669.2±615102.9±12104.1±12